5842 Overhead Blower

Configuration
Size
$1,987.70

Simco-Ion Model 5842 Enhanced Overhead Blower is a critical-environment, multi-fan overhead ionizing blower designed for cleanroom and controlled manufacturing areas where low offset voltage and consistent performance are required. Built on Steady-state DC technology, the 5842 delivers fast static charge neutralization from an overhead mounting position while supporting structured electrostatic control programs in ESD-sensitive areas.

The 5842 is available in 2-fan, 3-fan, and 4-fan configurations, with four fan-speed settings per configuration (high, med-high, med-low, low) to match ion delivery to the work area and process needs. For applications requiring the tightest balance control at the point of use, Novx Inside and Novx System versions can operate with Novx sensors to maintain precise balance (better than ±1V) by automatically adapting ion output to environmental changes.

Designed for critical environments with controlled contamination requirements, the 5842 is cleanliness rated to ISO 14644-1 Class 3 and includes sensor input, FMS connectivity, alarms, and management control features to support monitoring and rapid response to faults. Each fan includes a built-in Auto-clean System to automate emitter point cleaning and reduce maintenance time and cost.

  • Balance performance: ±3V or better; better than ±1V with Novx Inside or Novx System feedback control
  • Cleanliness rated to ISO 14644-1 Class 3
  • Available in 2-, 3-, or 4-fan configurations with four fan-speed settings per configuration
  • Sensor input, FMS connection, alarms, and management control for monitored environments
  • Built-in Auto-clean System on each fan for automated emitter point cleaning
  • Typical discharge: <2 sec @ 18" (45.7 cm), ±1000V to ±100V (overhead)
5842 Overhead Blower
1/3
Data Sheet

Request Literature

Thank you! Your request has been submitted.
There was an error submitting your request. Please try again.
Specification Value
Input Voltage 2-fan: 24 VDC, 1.0A max; 3-fan: 24 VDC, 1.5A max; 4-fan: 24 VDC, 2.0A max
Discharge <2 sec @ 18" (45.7 cm) overhead (±1000-100V)
Balance ±3V or better; ±1V with the Novx Inside or Novx System versions
Ion Emission Steady-state DC Technology
Emitter Titanium, 8 per fan
Cleanroom Class ISO 14644-1 Class 3
LED Indicator Green POWER on, red FAN stall, red FAULT with optional AUDIBLE ALARM
Control Power/fan speed DIP switch with 4 speed/velocity settings, balance adjustment, FMS connections
Audible Noise High fan speed 61 dB (typ), low fan speed 52 dB (typ); measurements taken 12" (30.5 cm) from fan
Airflow High: 129 cfm (typ/fan); Med-hi: 117 cfm; Med-low: 76 cfm; Low: 41 cfm
Ozone 0.005 ppm (typ)
Operating Environment 50-90°F (10-32°C); 30-70% RH, non-condensing
Option Audible alarm
Enclosure Aluminum chassis with epoxy-polyester powder coat
Dimension 2-fan: 32"L x 2.75"H x 5.44"W (81.3 x 6.99 x 13.82 cm)
3-fan: 42"L x 2.75"H x 5.44"W (106.68 x 6.99 x 13.82 cm)
4-fan: 52"L x 2.75"H x 5.44"W (132.08 x 6.99 x 13.82 cm)
Weight 2-fan: 5.5 lb (2.49 kg); 3-fan: 7.8 lb (3.55 kg); 4-fan: 10 lb (4.55 kg)
Note Specifications, configurations, and product images are subject to change without notice. Refer to the manufacturer's documentation for current details.

Critical cleanroom overhead ionization (ISO 14644-1 Class 3):
Provides overhead, multi-fan ionization for cleanroom work areas where contamination control and stable ion balance are required.

Low-balance ionization for ultra-sensitive processes:
Supports applications where low offset voltage is critical—especially when configured with Novx feedback control for precise balance at the target area.

ESD-sensitive assembly, inspection, and test:
Maintains controlled ionization coverage above work surfaces and process zones to reduce ESD risk during handling of sensitive components and assemblies.

Semiconductor and advanced electronics manufacturing:
Used in controlled environments where consistent ionization performance and monitoring are important for yield protection and process stability.

Overhead coverage of conveyors and defined process cells:
Installs above material flow and work cells to provide uniform ionization where point-of-use devices are impractical or would interfere with the process.

Monitored and alarmed production environments:
Supports facility monitoring and structured ESD control programs through alarm/status features and FMS connectivity for remote monitoring and response.

Part Number Description
**Standalone**
91-5842-32-NX01 5842 Blower 32" 2-Fan (Standalone), RoHS (24VDC input) (Not include Power Supply)
91-5842-32-NX01A 5842 Blower 32" 2-Fan (Standalone), Audible Alarm, RoHS (24VDC input) (Not include Power Adapter)
91-5842-42-NX01 5842 Blower 42" 3-Fan (Standalone), RoHS (24VDC input) (Not include Power Supply)
91-5842-42-NX01A 5842 Blower 42" 3-Fan (Standalone), Audible Alarm, RoHS (24VDC input) (Not include Power Adapter)
91-5842-52-NX01 5842 Blower 52" 4-Fan (Standalone), RoHS (24VDC input) (Not include Power Adapter)
91-5842-52-NX01A 5842 Blower 52" 4-Fan (Standalone), Audible Alarm, RoHS (24VDC input) (Not include Power Adapter)
**Novx Inside Version**
91-5842A-32-NX01 5842 Blower 32" 2-Fan Antenna (Novx Inside), RoHS (24VDC input) (Not include Power Adapter)
91-5842A-32-NX01A 5842 Blower 32" 2-Fan Antenna (Novx Inside), Audible Alarm, RoHS (24VDC input) (Not include Power Adapter)
91-5842A-42-NX01 5842 Blower 42" 3-Fan Antenna (Novx Inside), RoHS (24VDC input) (Not include Power Adapter)
91-5842A-42-NX01A 5842 Blower 42" 3-Fan Antenna (Novx Inside), Audible Alarm, RoHS (24VDC input) (Not include Power Adapter)
91-5842A-52-NX01 5842 Blower 52" 4-Fan Antenna (Novx Inside), RoHS (24VDC input) (Not include Power Adapter)
91-5842A-52-NX01A 5842 Blower 52" 4-Fan Antenna (Novx Inside), Audible Alarm, RoHS (24VDC input) (Not include Power Adapter)
**Novx System Version**
91-5842N-32-NX01 5842 Blower 32" 2-Fan Novx (Novx System), RoHS (24VDC input) (Not include Power Adapter)
91-5842N-32-NX01A 5842 Blower 32" 2-Fan Novx (Novx System), Audible Alarm, RoHS (24VDC input) (Not include Power Adapter)
91-5842N-42-NX01 5842 Blower 42" 3-Fan Novx (Novx System), RoHS (24VDC input) (Not include Power Adapter)
91-5842N-42-NX01A 5842 Blower 42" 3-Fan Novx (Novx System), Audible Alarm, RoHS (24VDC input) (Not include Power Adapter)
91-5842N-52-NX01 5842 Blower 52" 4-Fan Novx (Novx System), RoHS (24VDC input) (Not include Power Adapter)
91-5842N-52-NX01A 5842 Blower 52" 4-Fan Novx (Novx System), Audible Alarm, RoHS (24VDC input) (Not include Power Adapter)
Specifications, configurations, and product images are subject to change without notice. Refer to the manufacturer’s documentation for current details.

Works with

You might also consider

Contact us

585-924-8980
sales@empire-tech.net

Contact us

Thank you! We'll be in touch soon.
There was an error submitting your form. Please try again.