5810i Overhead Ionizing Blower

Length and Fan Count
Auto Emitter Point Cleaner
Audible Alarm
$1,884.30

The Simco-Ion Model 5810i Critical Environment Overhead Blower is designed to provide industry-leading balanced ionization performance in cleanroom and other critical manufacturing environments. The Model 5810i is certified for use in ISO 14644-1 Class 4 cleanrooms and is engineered for applications requiring precise electrostatic charge control and high ion output.

The 5810i can operate with Novx System external sensors, allowing the blower to maintain precise balance better than ±1V by actively adjusting ion output in response to environmental changes. Using steady-state DC technology-the established method for mitigating the effects of electrostatic discharge (ESD) and ESD-induced electromagnetic interference (EMI)-the Model 5810i delivers maximum ion output where and when it is needed.

Compatibility with modern cleanroom operating conditions is ensured through the use of silicone-free air-bearing fans. Each fan is engineered for cleanliness and sealed from the rest of the chassis to meet stringent critical-environment requirements. Ionization systems that do not meet these standards risk introducing contamination and potentially reducing manufacturing yields.


Features

  • Balanced ionization performance of ±3V or better
    (±1V when used with the Novx System)

  • ISO 14644-1 Class 4 cleanliness rating

  • Silicone-free air-bearing fans designed for critical environments

  • Optional sensor input, alarms, and management control interfaces

  • Optional Auto Emitter Point Cleaning System


Benefits

  • Provides effective corona-based ESD protection to help maximize product yield

  • Designed for use in environments with controlled levels of contamination

  • Enables increased control with immediate alarm notification and prevention of unauthorized adjustments to power or fan speed

  • Automated emitter point cleaning helps reduce maintenance time and cost

Need advanced control options such as FMS connectivity or Novx closed-loop balance control?

Contact Us

Our application engineers will review your requirements and confirm availability.

5810i Overhead Ionizing Blower
Data Sheet

Request Literature

Thank you! Your request has been submitted.
There was an error submitting your request. Please try again.
Specification Value
Input Voltage 100-240 VAC (±10%), 50/60 Hz
Output Voltage 100-240 VAC, 50/60 Hz unfused, 5 A max
Discharge < 3 sec (±1000 V to ±100 V) at 18 in (45.7 cm), high speed
Balance ±3 V (±1 V with Novx System external feedback)
Ionization Method Steady-state DC
Emitter Titanium emitters, 8 per fan
Cleanroom Classification ISO 14644-1 Class 4 (Fed. Std. 209E Class 10)
Airflow 108 CFM per fan (typical)
Audible Noise Low speed ~52 dB, high speed ~61 dB (typical)
Operating Temperature 50-90 °F (10-32 °C)
Operating Humidity 30-70% RH, non-condensing
Ozone ≤ 0.02 ppm
Daisy Chain Capability Up to 10 units via IEC power outlet
Mounting Eyebolts and S-hooks included; optional U-bracket or L-bracket
Dimensions 2-fan: 32 in L x 6.1 in D x 3.8 in H; 3-fan: 40 in or 44 in L x 6.1 in D x 3.8 in H
Weight 44 in model: approx. 10.3 lb (4.68 kg)
Warranty Two-year limited warranty
Specifications, configurations, and product images are subject to change without notice. Refer to the manufacturer's documentation for current details.

Provides overhead ionization for static charge neutralization in controlled environments where stable balance, cleanliness, and monitoring are required.

Cleanroom workstations: Neutralizes electrostatic charge over benches and work cells to reduce ESD risk and electrostatic attraction in ISO 14644-1 Class 4 environments.

ESD-sensitive assembly and inspection: Maintains controlled ion balance above sensitive electronic assemblies, components, and devices to support ESD protection during manual and semi-automated processes.

Overhead static control in manufacturing lines: Delivers uniform ionization coverage across defined process areas where parts move beneath the blower and direct point-of-use ionization is impractical.

Contamination-controlled environments: Supports particle control strategies by reducing electrostatic forces that contribute to particle attraction and recontamination in clean manufacturing spaces.

Monitored production environments: Integrates with Facility Monitoring Systems (FMS) to provide remote status and alarm signaling for ionization performance and fault conditions.

Item Part Number
Standard blower, fixed high fan speed, ±3 V balance (length dependent) 91-5810i-CzzH
Standard blower, low/high fan speed control, ±3 V balance (length dependent) 91-5810i-CzzX
Novx System blower, fixed high fan speed (length dependent) 92-5810i-CzzH
Novx System blower, low/high fan speed control (length dependent) 92-5810i-CzzX
Auto-Emitter Clean option suffix E
Audible alarm option suffix A
Lower balance limit to ±1 V (feedback option) F
Daisy-chain power cord 25-0720
U-shaped mounting bracket (2 required per blower) 32-6405
Specifications, configurations, and product images are subject to change without notice. Refer to the manufacturer’s documentation for current details.

Works with

You might also consider

Contact us

585-924-8980
sales@empire-tech.net

Contact us

Thank you! We'll be in touch soon.
There was an error submitting your form. Please try again.