Digital Room Ionization System Model 5515
$1,182.00
Ceiling Emitter Room Ionization System Provides Precision Control of All Ionization Parameters
The Model 5515 Ceiling Emitter and Controller Models 5522/5582 comprise our state-of-the-art digital room ionization system. Digital technology allows each ceiling emitter's parameters, including ion output, ion pulse timing or digital address, to be either individually set at its location using the Model 5571 and Model 5572 handheld controllers, or remotely set through IonManager Pro when integrated with the software. Precision fine tuning of each ceiling emitter enables the ionization system to achieve maximum performance in any airflow condition and for each application.
- Fully digital technology
- Single-crystal silicon or titanium emitter points
- Advanced Feedback Technology
- Small and large capacity controllers
l
| Specification | Value |
|---|---|
| Voltage | Input: 24 VAC, 50/60 Hz, 1W (typ) |
| Output: 0-20 kVDC for each polarity; positive and negative output levels adjusted separately | |
| Ion Emission | Pulsed DC, Steady-state DC, or Standby |
| Emitter | Single-crystal Silicon or Titanium, replaceable |
| Emitter Rod | 2.5, 5, 7.5, 10, 15, 24, 36, 48, 60, 66 inch (6.35, 12.7, 19.1, 25.4, 38.1, 61.0, 91.4, 122, 152, 168 cm), custom lengths are available |
| Cleanroom Class | Single-crystal Silicon ISO 14644-1 Class 1 or Titanium ISO 14644-1 Class 3 |
| Connector | Telephone-type RJ-11 modular jack receptacle on each end of emitter |
| Control Signal | Ionization parameters are adjusted with the 5571 Handheld Terminal, 5572 IR Remote, or via IonManager Pro software |
| Timing | Precise timing (0-10 sec @ 0.1 sec resolution) is generated by a local microcontroller; LEDs on each emitter indicate the polarity of the ion emission |
| Regulation | Output and balance stability is achieved by independently regulating the ion emission current of each polarity at each emitter |
| Alarm | Alarm operates when emitter is no longer able to maintain preset ion output level; visual LED in the middle of the emitter; optional audible alarm at controller |
| Ozone | <0.005 ppm |
| Operating Env | 59-95F (15-35C) nominal; 20-60% RH, non-condensing |
| Dimension | 1.2"H x 1.4"W x 17.5"L (3.05 x 3.56 x 44.5 cm) |
| Warranty | 10-year limited warranty |
| Weight | 1.03 lb (0.465 kg) |
| Specifications, configurations, and product images are subject to change without notice. Refer to the manufacturer's documentation for current details. |
| Item | Part Number |
|---|---|
| Emitter w/Titanium emitter points (2.5, 5, 7.5, 10, 15, 24, 36, 48, 60, 66 inch rod lengths) | 91-5515C-xxR |
| Emitter w/Silicon emitter points (2.5, 5, 7.5, 10, 15, 24, 36, 48, 60, 66 inch rod lengths) | 91-5515U-xxR |
| Digital Controller, supports up to 20 emitters | 91-5522-01 |
| Digital Controller, supports up to 80 emitters | 91-5582R |
| IonManager Pro software (x represents current version number) | 91-5582-SW-Vx |
| Infrared Remote Controller for 5515 emitter | 91-5572 |
| Handheld Terminal | 91-5571 |